Daily safety inspection for lead-acid and lithium-ion MHE charging stations, eyewash stations, ventilation fans, and charger cables.
Confirm exhaust fans are running to disperse hydrogen gas during lead-acid charging and verify no-smoking/no-open-flame signs are posted.
Check that the eyewash station is unobstructed within 10 seconds' walk, flush briefly to verify clean tepid water flow, and confirm acid spill kit is stocked.
Examine Anderson connectors and DC cables for melted insulation, exposed copper, or cracked housings, and inspect battery-lifting hoists and hooks.
Confirm acid-resistant aprons, face shields, and insulated gloves are stocked at the bay, and check drip trays under charging racks.
OSHA 1910.151(c) and 1910.178(g) require immediate flushing facilities where sulfuric acid electrolyte splashes can cause permanent eye damage within seconds.
Yes, for flooded lead-acid batteries, opening the hood dissipates heat and prevents explosive hydrogen gas from accumulating inside the battery compartment.
Mandatory pre-shift visual and operational inspection for counterbalance and electric forklifts before entering warehouse aisles.
Daily safety and mechanical check for loading dock bays, hydraulic dock levelers, trailer restraints, and dock plates before freight transfer.
Daily temperature, humidity, and door-seal verification log for refrigerated warehouses, blast chillers, and outbound reefer trailers.