Execute rigorous pre-batch GMP packaging line clearance to eliminate mix-ups, leftover labels, cartons, or tablets from the previous batch.
Clear all bulk product, blister foils, leaflets, printed cartons, and reject-bin contents from the line, conveyors, and floor.
Check under conveyor belts, inside tablet hoppers, and around blister sealing rollers with a flashlight to confirm zero residual units remain.
Confirm equipment 'Cleaned' status tags are signed and valid, and verify the new Batch Packaging Record (BPR) matches the room status board.
Verify overprinter batch/expiry settings against BPR and challenge the vision camera / checkweigher reject chute with a known bad test sample.
Independent verification by QA prevents confirmation bias and catches hidden residual labels or tablets that could cause a critical product mix-up or recall.
All unused pre-printed or coded labels must be reconciled against issued quantities and either destroyed under supervision or returned to a locked label store.
Monitor ISO-classified cleanroom positive/negative differential pressures (Magnehelic gauges), temperature, and relative humidity per shift to prevent cross-contamination.
Verify chemical fume hood face velocity (80–120 fpm), sash working height stop, and baffle airflow before handling volatile or toxic reagents.
Perform daily level-bubble check, internal/external weight verification with Class E2/F1 NIST weights, and sensitivity check on analytical balances.