Monitor walk-in pharmaceutical cold rooms (2°C–8°C) and locked quarantine cages for temperature uniformity, door alarms, and physical stock segregation.
Read the external digital controller and mapped high/low corner sensors to confirm uniform 2°C–8°C storage without cold spots near evaporator fans.
Verify the internal emergency push-button / man-trap bell works, strip curtains are intact, and the door-ajar alarm triggers within the configured delay.
Confirm all 'Quarantine', 'Under Test', and 'Rejected' materials are physically segregated in locked cages/racks with clear status labels (if not purely ERP-controlled).
Inspect evaporator drip pans and floor surfaces for ice buildup or condensation slip hazards and ensure pallets sit off the floor on clean racks.
GDP and WHO guidelines require seasonal thermal mapping to identify hot spots near doors and freezing zones directly beneath evaporator fans.
Quarantined or rejected batches must be either physically locked in dedicated, clearly labeled cages or controlled by a validated ERP system that blocks picking.
Monitor ISO-classified cleanroom positive/negative differential pressures (Magnehelic gauges), temperature, and relative humidity per shift to prevent cross-contamination.
Verify chemical fume hood face velocity (80–120 fpm), sash working height stop, and baffle airflow before handling volatile or toxic reagents.
Perform daily level-bubble check, internal/external weight verification with Class E2/F1 NIST weights, and sensitivity check on analytical balances.