Daily inspection of MIG/TIG/stick welding bays and hot-work zones covering fume extraction, cylinder chaining, flashback arrestors, fire extinguishers, and arc curtains.
Ensure a 35-foot radius (or fire-blanket barrier) is clear of flammables, cardboard, and solvents. Confirm an inspected ABC fire extinguisher is mounted within immediate reach.
Verify argon/CO2/oxygen/acetylene cylinders are chained upright at two-thirds height, regulators are leak-free without oil/grease, and oxy-fuel torches have flashback arrestors installed.
Inspect electrode leads and work-return ground cables for exposed copper or cracked insulation, verify tight ground clamp connection, and close UV-filtering welding curtains.
Turn on the fume extraction arm/hood and position it 6–12 inches from the weld zone. Confirm welders wear auto-darkening helmets, FR jackets, leather gloves, and safety glasses.
NFPA 51B and OSHA 1910.252 require a 35-foot (11-meter) radius free of combustible materials. If combustibles cannot be moved, they must be covered with fire-rated welding blankets and a dedicated fire watch must remain for at least 30–60 minutes after work ends.
Pure oxygen under pressure reacts violently with petroleum-based oils or greases, which can cause spontaneous ignition or explosion at the regulator valve.
Standardized pre-shift inspection for CNC machining centers covering coolant levels, way lube, spindle warm-up, and interlock guarding before cutting metal.
Daily safety and water-chemistry verification for industrial steam and hot-water boilers covering low-water cutoffs, relief valves, and burner flame stability.
Step-by-step hazardous energy control checklist ensuring electrical, pneumatic, hydraulic, gravitational, and thermal energy sources are isolated and zero-verified before servicing.